ion-sensitive field-effect transistors Search Results


90
Microsens Medtech ion-sensitive field effect transistor (isfet) msfet3351
Simplified circuit diagram. Components are shown in the 3D rendering (top) of the printed circuit board (PCB) and labeled by number corresponding to the schematic (bottom). Their voltage requirements and communication protocols are also shown. Blue boxes indicate components attached to the stretchable cables as shown in the top 3D rendering. Strain gauges (SG) were glued to the magnesium and titanium plates as two Wheatstone half-bridges, with bridge completion resistors (R) soldered to the PCB inside the titanium case. One bridge was used to measure axial loading and the other for measuring in-plane bending, by gluing the gauges appropriately. They were sampled with a 24-bit analog-to-digital converter (ADC, 3) that was converted to the correct voltage level (using the level shifter, 2) and communicated with the microcontroller (1) using the serial peripheral interface (SPI). The temperature sensors at two locations (osteotomy and reference) and the accelerometer (4) were read using the inter-integrated circuit (IIC) bus. The pH sensor <t>(ISFET),</t> whose gate-source voltage ( V GS ) was conditioned to linearly depend on pH (5), was amplified with a gain of 3.6 and read using a 12-bit ADC internal to the microcontroller. Data was stored in nonvolatile memory (6) using the quad serial peripheral interface (QSPI).
Ion Sensitive Field Effect Transistor (Isfet) Msfet3351, supplied by Microsens Medtech, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ion-sensitive+field-effect+transistors/ion+sensitive+field+effect+transistor++isfet++msfet3351/pmc11532740-84-6-38
Average 90 stars, based on 1 article reviews
ion-sensitive field effect transistor (isfet) msfet3351 - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Sentron Medical Inc ion-sensitive field-effect transistors (isfets)
Simplified circuit diagram. Components are shown in the 3D rendering (top) of the printed circuit board (PCB) and labeled by number corresponding to the schematic (bottom). Their voltage requirements and communication protocols are also shown. Blue boxes indicate components attached to the stretchable cables as shown in the top 3D rendering. Strain gauges (SG) were glued to the magnesium and titanium plates as two Wheatstone half-bridges, with bridge completion resistors (R) soldered to the PCB inside the titanium case. One bridge was used to measure axial loading and the other for measuring in-plane bending, by gluing the gauges appropriately. They were sampled with a 24-bit analog-to-digital converter (ADC, 3) that was converted to the correct voltage level (using the level shifter, 2) and communicated with the microcontroller (1) using the serial peripheral interface (SPI). The temperature sensors at two locations (osteotomy and reference) and the accelerometer (4) were read using the inter-integrated circuit (IIC) bus. The pH sensor <t>(ISFET),</t> whose gate-source voltage ( V GS ) was conditioned to linearly depend on pH (5), was amplified with a gain of 3.6 and read using a 12-bit ADC internal to the microcontroller. Data was stored in nonvolatile memory (6) using the quad serial peripheral interface (QSPI).
Ion Sensitive Field Effect Transistors (Isfets), supplied by Sentron Medical Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ion-sensitive+field-effect+transistors/ion+sensitive+field+effect+transistors++isfets/us09409028-378-54-62
Average 90 stars, based on 1 article reviews
ion-sensitive field-effect transistors (isfets) - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
honeywell international isfet ph sensors durafet
Simplified circuit diagram. Components are shown in the 3D rendering (top) of the printed circuit board (PCB) and labeled by number corresponding to the schematic (bottom). Their voltage requirements and communication protocols are also shown. Blue boxes indicate components attached to the stretchable cables as shown in the top 3D rendering. Strain gauges (SG) were glued to the magnesium and titanium plates as two Wheatstone half-bridges, with bridge completion resistors (R) soldered to the PCB inside the titanium case. One bridge was used to measure axial loading and the other for measuring in-plane bending, by gluing the gauges appropriately. They were sampled with a 24-bit analog-to-digital converter (ADC, 3) that was converted to the correct voltage level (using the level shifter, 2) and communicated with the microcontroller (1) using the serial peripheral interface (SPI). The temperature sensors at two locations (osteotomy and reference) and the accelerometer (4) were read using the inter-integrated circuit (IIC) bus. The pH sensor <t>(ISFET),</t> whose gate-source voltage ( V GS ) was conditioned to linearly depend on pH (5), was amplified with a gain of 3.6 and read using a 12-bit ADC internal to the microcontroller. Data was stored in nonvolatile memory (6) using the quad serial peripheral interface (QSPI).
Isfet Ph Sensors Durafet, supplied by honeywell international, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ion-sensitive+field-effect+transistors/durafet+ion+sensitive+field+effect+transistor++isfet++based+ph+sensor/10__1002_slash_lom3__10416-228-12-13
Average 90 stars, based on 1 article reviews
isfet ph sensors durafet - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Microsens Medtech integrated isfet-based ph sensor
Simplified circuit diagram. Components are shown in the 3D rendering (top) of the printed circuit board (PCB) and labeled by number corresponding to the schematic (bottom). Their voltage requirements and communication protocols are also shown. Blue boxes indicate components attached to the stretchable cables as shown in the top 3D rendering. Strain gauges (SG) were glued to the magnesium and titanium plates as two Wheatstone half-bridges, with bridge completion resistors (R) soldered to the PCB inside the titanium case. One bridge was used to measure axial loading and the other for measuring in-plane bending, by gluing the gauges appropriately. They were sampled with a 24-bit analog-to-digital converter (ADC, 3) that was converted to the correct voltage level (using the level shifter, 2) and communicated with the microcontroller (1) using the serial peripheral interface (SPI). The temperature sensors at two locations (osteotomy and reference) and the accelerometer (4) were read using the inter-integrated circuit (IIC) bus. The pH sensor <t>(ISFET),</t> whose gate-source voltage ( V GS ) was conditioned to linearly depend on pH (5), was amplified with a gain of 3.6 and read using a 12-bit ADC internal to the microcontroller. Data was stored in nonvolatile memory (6) using the quad serial peripheral interface (QSPI).
Integrated Isfet Based Ph Sensor, supplied by Microsens Medtech, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ion-sensitive+field-effect+transistors/msfet+3351+ion+sensitive+field+effect+transistor++isfet+/pmc07956188-322-6-0
Average 90 stars, based on 1 article reviews
integrated isfet-based ph sensor - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Microsensors Inc ion selective field effect transistors
Simplified circuit diagram. Components are shown in the 3D rendering (top) of the printed circuit board (PCB) and labeled by number corresponding to the schematic (bottom). Their voltage requirements and communication protocols are also shown. Blue boxes indicate components attached to the stretchable cables as shown in the top 3D rendering. Strain gauges (SG) were glued to the magnesium and titanium plates as two Wheatstone half-bridges, with bridge completion resistors (R) soldered to the PCB inside the titanium case. One bridge was used to measure axial loading and the other for measuring in-plane bending, by gluing the gauges appropriately. They were sampled with a 24-bit analog-to-digital converter (ADC, 3) that was converted to the correct voltage level (using the level shifter, 2) and communicated with the microcontroller (1) using the serial peripheral interface (SPI). The temperature sensors at two locations (osteotomy and reference) and the accelerometer (4) were read using the inter-integrated circuit (IIC) bus. The pH sensor <t>(ISFET),</t> whose gate-source voltage ( V GS ) was conditioned to linearly depend on pH (5), was amplified with a gain of 3.6 and read using a 12-bit ADC internal to the microcontroller. Data was stored in nonvolatile memory (6) using the quad serial peripheral interface (QSPI).
Ion Selective Field Effect Transistors, supplied by Microsensors Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ion-sensitive+field-effect+transistors/ion+sensitive+field+effect+transistors/us09955896-87-13-20
Average 90 stars, based on 1 article reviews
ion selective field effect transistors - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
honeywell international ion-sensitive field-effect transistor honeywell durafet ii
Simplified circuit diagram. Components are shown in the 3D rendering (top) of the printed circuit board (PCB) and labeled by number corresponding to the schematic (bottom). Their voltage requirements and communication protocols are also shown. Blue boxes indicate components attached to the stretchable cables as shown in the top 3D rendering. Strain gauges (SG) were glued to the magnesium and titanium plates as two Wheatstone half-bridges, with bridge completion resistors (R) soldered to the PCB inside the titanium case. One bridge was used to measure axial loading and the other for measuring in-plane bending, by gluing the gauges appropriately. They were sampled with a 24-bit analog-to-digital converter (ADC, 3) that was converted to the correct voltage level (using the level shifter, 2) and communicated with the microcontroller (1) using the serial peripheral interface (SPI). The temperature sensors at two locations (osteotomy and reference) and the accelerometer (4) were read using the inter-integrated circuit (IIC) bus. The pH sensor <t>(ISFET),</t> whose gate-source voltage ( V GS ) was conditioned to linearly depend on pH (5), was amplified with a gain of 3.6 and read using a 12-bit ADC internal to the microcontroller. Data was stored in nonvolatile memory (6) using the quad serial peripheral interface (QSPI).
Ion Sensitive Field Effect Transistor Honeywell Durafet Ii, supplied by honeywell international, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ion-sensitive+field-effect+transistors/ion+sensitive+field+effect+transistor+honeywell+durafet+ii/10__1029_slash_2020jg005812-66-1-4
Average 90 stars, based on 1 article reviews
ion-sensitive field-effect transistor honeywell durafet ii - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Laborie Medical Technologies Inc ion-sensitive field-effect transistor (isfet) disposable ph-mii catheters
Simplified circuit diagram. Components are shown in the 3D rendering (top) of the printed circuit board (PCB) and labeled by number corresponding to the schematic (bottom). Their voltage requirements and communication protocols are also shown. Blue boxes indicate components attached to the stretchable cables as shown in the top 3D rendering. Strain gauges (SG) were glued to the magnesium and titanium plates as two Wheatstone half-bridges, with bridge completion resistors (R) soldered to the PCB inside the titanium case. One bridge was used to measure axial loading and the other for measuring in-plane bending, by gluing the gauges appropriately. They were sampled with a 24-bit analog-to-digital converter (ADC, 3) that was converted to the correct voltage level (using the level shifter, 2) and communicated with the microcontroller (1) using the serial peripheral interface (SPI). The temperature sensors at two locations (osteotomy and reference) and the accelerometer (4) were read using the inter-integrated circuit (IIC) bus. The pH sensor <t>(ISFET),</t> whose gate-source voltage ( V GS ) was conditioned to linearly depend on pH (5), was amplified with a gain of 3.6 and read using a 12-bit ADC internal to the microcontroller. Data was stored in nonvolatile memory (6) using the quad serial peripheral interface (QSPI).
Ion Sensitive Field Effect Transistor (Isfet) Disposable Ph Mii Catheters, supplied by Laborie Medical Technologies Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ion-sensitive+field-effect+transistors/ion+sensitive+field+effect+transistor++isfet++disposable+ph+mii+catheters/pmc06855319-77-36-30
Average 90 stars, based on 1 article reviews
ion-sensitive field-effect transistor (isfet) disposable ph-mii catheters - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Satlantic Inc ion sensitive field effect transistor (isfet)-based solid state pht (total scale) seafet sensor
Simplified circuit diagram. Components are shown in the 3D rendering (top) of the printed circuit board (PCB) and labeled by number corresponding to the schematic (bottom). Their voltage requirements and communication protocols are also shown. Blue boxes indicate components attached to the stretchable cables as shown in the top 3D rendering. Strain gauges (SG) were glued to the magnesium and titanium plates as two Wheatstone half-bridges, with bridge completion resistors (R) soldered to the PCB inside the titanium case. One bridge was used to measure axial loading and the other for measuring in-plane bending, by gluing the gauges appropriately. They were sampled with a 24-bit analog-to-digital converter (ADC, 3) that was converted to the correct voltage level (using the level shifter, 2) and communicated with the microcontroller (1) using the serial peripheral interface (SPI). The temperature sensors at two locations (osteotomy and reference) and the accelerometer (4) were read using the inter-integrated circuit (IIC) bus. The pH sensor <t>(ISFET),</t> whose gate-source voltage ( V GS ) was conditioned to linearly depend on pH (5), was amplified with a gain of 3.6 and read using a 12-bit ADC internal to the microcontroller. Data was stored in nonvolatile memory (6) using the quad serial peripheral interface (QSPI).
Ion Sensitive Field Effect Transistor (Isfet) Based Solid State Pht (Total Scale) Seafet Sensor, supplied by Satlantic Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ion-sensitive+field-effect+transistors/ion+sensitive+field+effect+transistor++isfet++based+solid+state+pht++total+scale++seafet+sensor/10__3389_slash_fmars__2021__720175-60-54-60
Average 90 stars, based on 1 article reviews
ion sensitive field effect transistor (isfet)-based solid state pht (total scale) seafet sensor - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
DNA Electronics ion sensitive field effect transistor (isfet)
Simplified circuit diagram. Components are shown in the 3D rendering (top) of the printed circuit board (PCB) and labeled by number corresponding to the schematic (bottom). Their voltage requirements and communication protocols are also shown. Blue boxes indicate components attached to the stretchable cables as shown in the top 3D rendering. Strain gauges (SG) were glued to the magnesium and titanium plates as two Wheatstone half-bridges, with bridge completion resistors (R) soldered to the PCB inside the titanium case. One bridge was used to measure axial loading and the other for measuring in-plane bending, by gluing the gauges appropriately. They were sampled with a 24-bit analog-to-digital converter (ADC, 3) that was converted to the correct voltage level (using the level shifter, 2) and communicated with the microcontroller (1) using the serial peripheral interface (SPI). The temperature sensors at two locations (osteotomy and reference) and the accelerometer (4) were read using the inter-integrated circuit (IIC) bus. The pH sensor <t>(ISFET),</t> whose gate-source voltage ( V GS ) was conditioned to linearly depend on pH (5), was amplified with a gain of 3.6 and read using a 12-bit ADC internal to the microcontroller. Data was stored in nonvolatile memory (6) using the quad serial peripheral interface (QSPI).
Ion Sensitive Field Effect Transistor (Isfet), supplied by DNA Electronics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ion-sensitive+field-effect+transistors/ion+sensitive+field+effect+transistor++isfet+/us08597882-266-27-10
Average 90 stars, based on 1 article reviews
ion sensitive field effect transistor (isfet) - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
DNA Electronics ion-sensitive field effect transistors (isfets) genalysis
Commercially available DNA sensors and microarrays platforms.
Ion Sensitive Field Effect Transistors (Isfets) Genalysis, supplied by DNA Electronics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ion-sensitive+field-effect+transistors/ion+sensitive+field+effect+transistors++isfets++genalysis/pmc04507582-32-7-0
Average 90 stars, based on 1 article reviews
ion-sensitive field effect transistors (isfets) genalysis - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
BioSensing Technologies Ltd ion-sensitive field-effect transistor (isfet)-based
Variations of “passive” electric sensing configurations using the gate of MOS as sensing input. ( a ) Capacitive coupling; ( b ) Conductive coupling; and ( c ) <t>ISFET</t> type.
Ion Sensitive Field Effect Transistor (Isfet) Based, supplied by BioSensing Technologies Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ion-sensitive+field-effect+transistors/ion+sensitive+field+effect+transistor++isfet++based/pmc05448479-19-30-34
Average 90 stars, based on 1 article reviews
ion-sensitive field-effect transistor (isfet)-based - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Controlled Fluidics ion-sensitive field-effect transistors isfet
Variations of “passive” electric sensing configurations using the gate of MOS as sensing input. ( a ) Capacitive coupling; ( b ) Conductive coupling; and ( c ) <t>ISFET</t> type.
Ion Sensitive Field Effect Transistors Isfet, supplied by Controlled Fluidics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ion-sensitive+field-effect+transistors/ion+sensitive+field+effect+transistors+isfet/pm27877886-1-4-10
Average 90 stars, based on 1 article reviews
ion-sensitive field-effect transistors isfet - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


Simplified circuit diagram. Components are shown in the 3D rendering (top) of the printed circuit board (PCB) and labeled by number corresponding to the schematic (bottom). Their voltage requirements and communication protocols are also shown. Blue boxes indicate components attached to the stretchable cables as shown in the top 3D rendering. Strain gauges (SG) were glued to the magnesium and titanium plates as two Wheatstone half-bridges, with bridge completion resistors (R) soldered to the PCB inside the titanium case. One bridge was used to measure axial loading and the other for measuring in-plane bending, by gluing the gauges appropriately. They were sampled with a 24-bit analog-to-digital converter (ADC, 3) that was converted to the correct voltage level (using the level shifter, 2) and communicated with the microcontroller (1) using the serial peripheral interface (SPI). The temperature sensors at two locations (osteotomy and reference) and the accelerometer (4) were read using the inter-integrated circuit (IIC) bus. The pH sensor (ISFET), whose gate-source voltage ( V GS ) was conditioned to linearly depend on pH (5), was amplified with a gain of 3.6 and read using a 12-bit ADC internal to the microcontroller. Data was stored in nonvolatile memory (6) using the quad serial peripheral interface (QSPI).

Journal: Bioactive Materials

Article Title: Development of an implantable sensor system for in vivo strain, temperature, and pH monitoring: comparative evaluation of titanium and resorbable magnesium plates

doi: 10.1016/j.bioactmat.2024.09.015

Figure Lengend Snippet: Simplified circuit diagram. Components are shown in the 3D rendering (top) of the printed circuit board (PCB) and labeled by number corresponding to the schematic (bottom). Their voltage requirements and communication protocols are also shown. Blue boxes indicate components attached to the stretchable cables as shown in the top 3D rendering. Strain gauges (SG) were glued to the magnesium and titanium plates as two Wheatstone half-bridges, with bridge completion resistors (R) soldered to the PCB inside the titanium case. One bridge was used to measure axial loading and the other for measuring in-plane bending, by gluing the gauges appropriately. They were sampled with a 24-bit analog-to-digital converter (ADC, 3) that was converted to the correct voltage level (using the level shifter, 2) and communicated with the microcontroller (1) using the serial peripheral interface (SPI). The temperature sensors at two locations (osteotomy and reference) and the accelerometer (4) were read using the inter-integrated circuit (IIC) bus. The pH sensor (ISFET), whose gate-source voltage ( V GS ) was conditioned to linearly depend on pH (5), was amplified with a gain of 3.6 and read using a 12-bit ADC internal to the microcontroller. Data was stored in nonvolatile memory (6) using the quad serial peripheral interface (QSPI).

Article Snippet: The pH sensor consists of an ion-sensitive field effect transistor (ISFET) that has a sensing area of 1.2 × 3 mm 2 with a 2 mm diameter Ag/AgCl reference electrode combined in a 10 mm diameter package (MSFET3351, Microsens SA, Switzerland).

Techniques: Labeling, Amplification

Commercially available DNA sensors and microarrays platforms.

Journal: Sensors (Basel, Switzerland)

Article Title: DNA-Based Nanobiosensors as an Emerging Platform for Detection of Disease

doi: 10.3390/s150614539

Figure Lengend Snippet: Commercially available DNA sensors and microarrays platforms.

Article Snippet: DNA Electronics Ltd, London , UK , Genalysis ® , ion-sensitive field effect transistors (ISFETs) based , http://dnae.co.uk.

Techniques: Fluorescence, Polymerase Chain Reaction, Biomarker Discovery, Gene Expression, Microarray, Quantitation Assay, Flow Cytometry, Next-Generation Sequencing, Real-time Polymerase Chain Reaction, Sequencing, Diagnostic Assay, In Vitro, DNA Methylation Assay, Synthesized, In Situ, Expressing, Labeling

Variations of “passive” electric sensing configurations using the gate of MOS as sensing input. ( a ) Capacitive coupling; ( b ) Conductive coupling; and ( c ) ISFET type.

Journal: Materials

Article Title: Optical and Electric Multifunctional CMOS Image Sensors for On-Chip Biosensing Applications

doi: 10.3390/ma4010084

Figure Lengend Snippet: Variations of “passive” electric sensing configurations using the gate of MOS as sensing input. ( a ) Capacitive coupling; ( b ) Conductive coupling; and ( c ) ISFET type.

Article Snippet: This structural feature means that conventional CMOS is natively compatible with not only electric sensing schemes that use the metal wiring layer as the sensing electrode, but also implementation of ion-sensitive field-effect transistor (ISFET)-based biosensing technologies [ , , , , , , , , , , ].

Techniques: